
In Stock
10 inch Backdraft Damper
☆☆☆☆☆
$40.98
Choosing a 10 inch Backdraft Damper for a Bigger Run
Blade mass climbs with diameter, and at ten inches that becomes something to think about rather than ignore. Each blade is a larger plate than the same part in a six or an eight, and a larger plate takes more air to lift.
Purchase directly from Growers HouseChoosing a 10 inch Backdraft Damper for a Bigger Run
Blade mass climbs with diameter, and at ten inches that becomes something to think about rather than ignore. Each blade is a larger plate than the same part in a six or an eight, and a larger plate takes more air to lift. Atmosphere give the requirement as four to eight hundredths of an inch of static pressure across the range. A well specified ten inch fan at full speed clears that comfortably. A ten inch fan turned down to a low night setting is the case to check. A damper that only half opens strangles the run, and the fan sounds fine while doing almost nothing. Test at the slowest speed the system will be asked to run. Beyond that the design is the same across the range. Two blades hang on independent hinges so one cannot hold the other open. Both seat onto a neoprene perimeter gasket for a quiet, tight closure.
Galvanized Steel, Installation and Keeping It Working
The body is galvanized steel, which is the right material for a part that sits inside a humid extraction duct for years. Zinc coating takes the corrosion that plain steel would not survive, and the stiffness keeps a plate this size from distorting and losing its seal. The whole assembly inserts into the duct rather than bolting to a flange. Installation is a push fit and a couple of screws rather than a fabrication job. Any orientation works, including a vertical riser. A few habits keep it doing its job. Support the duct either side so the damper is not carrying the weight of a sagging run. Keep the sealing face clean, since dust and resin build on it and a face that cannot seat leaks without making any noise about it. Check the blades swing freely at each filter change. A damper is the lowest cost part in a ventilation run and the easiest to forget about entirely.
Key Features
Duct size: Ten inches, for a larger extraction or supply run
Blade mass: Larger plates than a smaller size, so opening pressure matters more
Opening pressure: Four to eight hundredths of an inch of static
Low speed check: Test that it opens at the slowest speed the fan will run
Blades: Two, each on its own independent hinge
Seal: Neoprene perimeter gasket for a quiet, tight closure
Body: Galvanized steel, chosen for a humid duct environment
Mounting: Inserts into the duct, with no flange or transition needed
Support: Hold the duct either side so the damper carries no weight
Maintenance: Clean the sealing face and check the swing at each filter change
Technical Specifications
Specification
Value
SKU
VTBDD10
Duct diameter
10 in
Brand
Atmosphere
Type
Round backdraft damper, duct insert
Material
Galvanized steel
Blades
Two, each on its own independent hinge
Seal
Neoprene perimeter gasket
Mounting
The whole assembly inserts into the duct
Orientation
Installs in any position
Opening pressure
0.04 to 0.08 in of static pressure
Designed for
Atmosphere Vortex in-line fans and dryer exhaust ventilators
Barcode
628507200053






