In Stock
Growlink Batch TankLINK EC Sensor
☆☆☆☆☆
$134.99
Reading Conductivity with the Growlink Batch TankLINK EC Sensor
The Growlink Batch TankLINK EC Sensor measures nutrient solution conductivity inside a batch tank in real time. The probe reads across a 0–7,000 µS range. Accuracy is ±20 µS below 2,000 µS and ±50 µS above that.
Purchase directly from Growers HouseReading Conductivity with the Growlink Batch TankLINK EC Sensor
The Growlink Batch TankLINK EC Sensor measures nutrient solution conductivity inside a batch tank in real time. The probe reads across a 0–7,000 µS range. Accuracy is ±20 µS below 2,000 µS and ±50 µS above that. Resolution is 2 µS — roughly 0.02 mS/cm in PPM-meter terms. A 10-foot cable runs from the probe to the Batch TankLINK controller's labeled screw terminal block. The cable also carries a PT1000 element that gives the controller automatic temperature compensation on every reading. Calibration is a single-point process at 1413 µS. Drop the probe into calibration solution alongside the temperature probe to lock in the cal pass.
Wiring the TankLINK EC Probe into a Recirculation Loop
Most batch-tank installs run a separate probe per recirculation loop. The 10-foot cable covers tanks within reach of the controller. The 30-foot option (available separately) handles longer runs where the controller mounts wall-side and the tank sits across the room. Growers usually position this TankLINK EC probe near the recirculation return for a representative read. Pair the data with the TankLINK's automated dosing and refill triggers and the nutrient solution EC sensor holds the line to setpoint between batches. PT1000-compensated readings also mean morning EC checks match afternoon checks even when the room runs 8°F warmer under lights. Plug-and-play wiring keeps a single-probe swap during teardown to a few minutes. No driver shuffling — just the batch tank conductivity probe back into the terminal block and a fresh 1413 µS recalibrate. Most rooms swap the probe at the start of each season or when calibration drift crosses ±50 µS at the cal point.
Key Features
0–7,000 µS Range: Covers the full PPM band growers feed across veg, transition, and bloom in one probe.
Tiered Accuracy: ±20 µS below 2,000 µS and ±50 µS above — tight enough to catch real EC drift between feeds.
Built-In PT1000 Compensation: The cable carries a temperature element so readings stay honest across an 8°F lights-on swing.
10 ft Cable Standard: Reaches most controller-to-tank layouts; a 30 ft version is available separately for longer runs.
Single-Point Calibration: One 1413 µS solution and the LCD wizard handle the full cal — no two-point dance required.
Technical Specifications
Specification
Value
EC Range
0–7,000 µS
Accuracy
±20 µS (<2,000 µS); ±50 µS (>2,000 µS)
Resolution
2 µS
Temperature Compensation
Built-in PT1000 element in cable
Cable Length
10 ft (3 m); 30 ft available separately
Calibration
Single-point @ 1413 µS via LCD wizard
Connection
Screw terminal block on Batch TankLINK transmitter
Compatible Controller
Growlink Batch TankLINK