In Stock
Hanna HI98103 pH Checker Starter Kit | 16 oz pH 4 and pH 7 Buffers
☆☆☆☆☆
$65.56
What the Hanna pH Checker Actually Resolves
The HI98103 reads 0.0 to 14.0 pH, with a resolution of 0.1 pH and an accuracy of plus or minus 0.2 pH at room temperature. Resolution is the whole basis for choosing a pH tester.
Purchase directly from Growers HouseWhat the Hanna pH Checker Actually Resolves
The HI98103 reads 0.0 to 14.0 pH, with a resolution of 0.1 pH and an accuracy of plus or minus 0.2 pH at room temperature. Resolution is the whole basis for choosing a pH tester. For a grower holding a reservoir near a target of 5.8, a tenth of a point is usable and the tolerance is workable. Anyone who needs hundredths should be looking at a different tester rather than this one. What it does well is calibrate itself: automatic at one or two points, with the buffer recognised and tagged on the display. A stability hourglass tells you when to read, and the auto shut off can be set to 8 minutes, 60 minutes or disabled. The CR2032 lithium cell runs roughly 1000 hours, and the body measures 174 mm long by 50 mm wide.
Why the Kit Adds Full Bottles of Calibration Solution
Calibration solution is the part people run out of, and the bare meter ships with sachets rather than bottles. Two 20 mL pH 4.01 sachets and two of pH 7.01 go a very short way if you calibrate weekly. This kit adds 16 oz bottles of each, which is the practical difference between it and the tester alone. Hanna make their pH 4 buffer from potassium hydrogen phthalate and their pH 7 from potassium dihydrogen phosphate with disodium hydrogen phosphate. Both are standardised against NIST primary standard buffers, and every bottle carries a lot number, an expiry date and a pH against temperature chart. That chart matters because buffer values shift with temperature, so a cold bottle calibrates to a different number than a warm one. Never pour used buffer back into the bottle, and never calibrate in the bottle itself. Decant a little into a cup, use it, discard it. The electrode unscrews from the meter body, so a tired probe is a part rather than a new meter. Two cleaning solution sachets come with the tester, and a probe that reads slowly usually wants cleaning before it wants replacing.
Key Features
Meter: Hanna HI98103 Checker, with a replaceable electrode
Range: 0.0 to 14.0 pH across the full scale
Resolution: 0.1 pH
Accuracy: Plus or minus 0.2 pH
Calibration: Automatic at one or two points, with buffer recognition
Reading aid: Stability indicator and calibration tags on the display
Auto shut off: 8 minutes, 60 minutes, or disabled
Battery: CR2032 lithium, roughly 1000 hours of use
Kit adds: 16 oz bottles of pH 4 and pH 7 buffer
Buffer traceability: Standardised against NIST primary standard buffers
Technical Specifications
Specification
Value
SKU
HPHCCSK47CS
Brand
Hanna Instruments
Meter model
HI98103 Checker pH tester
pH range
0.0 to 14.0 pH
Resolution
0.1 pH
Accuracy
Plus or minus 0.2 pH at 25 degrees Celsius
Calibration
Automatic, one or two points, automatic buffer recognition
Electrode
HI1271, gel filled, replaceable by unscrewing
Electrode tip
Tapers to 8 mm at the sensing end
Auto shut off
8 min, 60 min or disabled
Battery
CR2032 lithium, about 1000 hours continuous
Meter dimensions
174 mm x 50 mm x 21 mm
Meter weight
About 50 grams
Supplied with the meter
Electrode, 2 x 20 mL pH 4.01, 2 x 20 mL pH 7.01, 2 x 20 mL cleaning solution, battery, manual, certificate, case
Kit adds
pH 4 buffer 16 oz and pH 7 buffer 16 oz
pH 4 buffer chemistry
Potassium hydrogen phthalate
pH 7 buffer chemistry
Potassium dihydrogen phosphate and disodium hydrogen phosphate
On every buffer bottle
Lot number, expiry date and a pH against temperature chart