In Stock
TrolMaster BETA-4 Day and Night Temperature Controller | 40-100 F
☆☆☆☆☆
$73.32
How the TrolMaster Beta-4 Handles Day and Night Apart
Two set points rather than one is the reason to choose this over a plain thermostat. A room under lamps carries a heat load that disappears when they go off. A single target then either overcools in the dark or undercools in the light.
Purchase directly from Growers HouseHow the TrolMaster Beta-4 Handles Day and Night Apart
Two set points rather than one is the reason to choose this over a plain thermostat. A room under lamps carries a heat load that disappears when they go off. A single target then either overcools in the dark or undercools in the light. The Beta-4 holds a separate figure for each and moves between them on its own. A photocell built into the unit does that switching by reading room light. Nothing has to be wired to the lighting circuit, and no timer has to be kept in step with it. The control range is forty to a hundred degrees Fahrenheit. Three buttons and a digital display cover the whole interface. A temperature sensor comes in the box alongside the controller. The device being switched plugs into an outlet on the underside of the unit, which keeps the installation to two plugs and a sensor lead.
The Deadband and the Load Rating
The deadband on this unit is fixed at five degrees Fahrenheit, and that number is worth understanding before it goes in. Deadband is the gap between switching on and switching off. Five degrees is wide, which protects a compressor from short cycling and suits an air conditioner or a heater well. It also means the room genuinely swings five degrees, so anything wanting tighter control needs a different device. Now the part to check before connecting anything. The fitted fuse is rated at six amps at two hundred and fifty volts. Keep the connected load below six amps. The output switch is a triac. Input is a hundred and twenty volts AC on a 1.8 m cord, and the packed unit is 275 by 87 by 94 mm at 0.56 kg.
Key Features
Set points: Separate day and night temperature targets held by the unit
Switching: A built-in photocell reads room light and changes between them
Control range: Forty to a hundred degrees Fahrenheit
Deadband: Fixed at five degrees Fahrenheit, which is a wide band
Short cycling: That wide band protects a compressor from rapid switching
Interface: Three buttons and a digital display
Connection: The controlled device plugs into an outlet on the underside
Output type: A triac, which is a solid state switch for alternating current
Load limit: Keep the connected load within the six amp fuse
In the box: The controller and a temperature sensor
Technical Specifications
Specification
Value
SKU
BETA-4
Brand
TrolMaster
Type
Day and night temperature controller
Input voltage
120 VAC
Output switch
Triac
Fuse rating
6 A at 250 V
Power cord
1.8 m
Temperature control range
40 to 100 F
Temperature deadband
5 F, fixed
Day and night switching
By built-in photocell
Package dimensions
275 x 87 x 94 mm
Package weight
0.56 kg
Package contents
1 temperature controller and 1 temperature sensor
Barcode
6970207970441