In Stock
AXEON N-Series Reverse Osmosis System – 2,000 GPD
☆☆☆☆☆
$6,140.03
AXEON® N-Series Reverse Osmosis Systems are designed as a competitive, turn-key solution for capacities ranging from 2,000 to 16,000 gallons per day.
Purchase directly from HydroBuilderAXEON® N-Series Reverse Osmosis Systems are designed as a competitive, turn-key solution for capacities ranging from 2,000 to 16,000 gallons per day. Used in indoor grow rooms, large commercial grow facilities, private residences, restaurants, car washes, hydroponics, misting applications, and more, the N-Series delivers reliable, high-rejection purified water right out of the box.
For growers, the N-Series provides a clean, low-TDS feed water baseline - reducing dissolved solids by up to 98.5% - giving you full control over your nutrient program from day one. The built-in AX-8000 controller monitors TDS, temperature, and pressure in real time, so you always know what your system is producing. Each unit ships pre-plumbed, wired, and fully assembled. Available in six capacities from 2,000 to 16,000 GPD - select the size that matches your daily water demand below.
Features
AX-8000 Computer Controller with LCD backlit display
Pre-treatment lockout and feed flush
TDS and temperature monitoring
Low and high pressure monitoring and alarm
Manual flush and tank level input
Pre-plumbed, wired, and fully assembled - ready to run on delivery
Individually tested before shipping
1-year limited warranty
Assembled in the U.S.A.
Included Components
AXEON XE1-Series 4" x 40" Membrane Elements
AXEON SDF-Series 4.5" x 20" 5-Micron Sediment Pre-Filter
Pentair® Big Grey Filter Housings
Grundfos® Multi-Stage Stainless Steel Booster Pump
Parker®/Seatech® Push/Pull Quick Connect Fittings
Black Powder Coated Aluminum Frame
Optional: AXEON N-Series White Protective Cover (sold separately)
Full Series Specifications
N-2000
N-4000
N-6000
N-8000
N-12000
N-16000
Design
Configuration
Single Pass
Single Pass
Single Pass
Single Pass
Single Pass
Single Pass
Max Feedwater TDS (ppm)
2,000
2,000
2,000
2,000
2,000
2,000
Standard Recovery %
32
48
58
65
58
65
Flow Rates
Permeate Flow (gpd / lpd)
2,000 / 7,570
4,000 / 15,141
6,000 / 22,712
8,000 / 30,283
12,000 / 45,425
16,000 / 60,566
Permeate Flow (gpm / lpm)
1.39 / 5.26
2.78 / 10.52
4.16 / 15.75
5.56 / 21.05
8.33 / 31.53
11.11 / 42.06
Min Concentrate Flow (gpm / lpm)
3 / 11.36
3 / 11.36
3 / 11.36
3 / 11.36
6 / 22.72
6 / 22.72
Connections
Feed
1" FNPT
1" FNPT
1" FNPT
1" FNPT
1" FNPT
1" FNPT
Permeate
1/2" QC
1/2" QC
1" FNPT
1" FNPT
1" FNPT
1" FNPT
Concentrate
1/2" QC
1/2" QC
1" FNPT
1" FNPT
1" FNPT
1" FNPT
Membranes
Membrane Quantity
1
2
3
4
6
8
Membrane Size
4040
4040
4040
4040
4040
4040
Nominal TDS Rejection %
98.50
98.50
98.50
98.50
98.50
98.50
Vessels
Vessel Array
1
1:1
1:1:1
1:1:1:1
2:2:2
2:2:2:2
Vessel Quantity
1
2
3
4
6
8
Pump
Pump Type
Multi-Stage
Multi-Stage
Multi-Stage
Multi-Stage
Multi-Stage
Multi-Stage
Motor HP
1.5
1.5
2
2
2
2
Electrical
Voltage / Amp Draw
220V, 60Hz, 1PH, 8.5A
220V, 60Hz, 1PH, 8.5A
220V, 60Hz, 1PH, 11.0A
220V, 60Hz, 1PH, 11.0A
220V, 60Hz, 1PH, 11.0A
220V, 60Hz, 1PH, 11.0A
Dimensions / Weight
Approx. Dimensions LxWxH (in)
25x16x55
25x16x55
25x16x55
25x16x55
25x16x55
25x16x55
Approx. Weight (lbs)
120
130
180
210
240
270
Test Parameters: 550 TDS Filtered (5-Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 100 psi / 6.9 bar Operating Pressure, 77 degrees F / 25 degrees C, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation. Low temperatures and high feedwater TDS will significantly affect production - consult your dealer if feed water conditions do not meet operating limits.
Operating Limits
Max Feed Temperature
85 degrees F / 29 degrees C
Max Turbidity
1 NTU
Min Feed Temperature
40 degrees F / 4 degrees C
Max Free Chlorine
0 ppm
Max Ambient Temperature
120 degrees F / 49 degrees C
Max TDS
2,000 ppm
Min Ambient Temperature
40 degrees F / 4 degrees C
Max Hardness
0 gpg
Max Feed Pressure
85 psi / 6 bar
Max pH (continuous)
11
Min Feed Pressure
45 psi / 3 bar
Min pH (continuous)
2
Max Operating Pressure
200 psi / 14 bar
Max SDI
< 3
If feed water parameters fall outside these limits, consult your dealer or contact us at 888-815-9763 before installation.
N-Series Accessories & Replacement Parts
AXEON S-200 Membrane Antiscalant - helps prevent membrane fouling and extends membrane life
Shop all AXEON Water Filtration at Hydrobuilder
Outfitting a commercial grow facility? Our team handles facility-scale RO sizing, installation planning, and volume orders. Set up a commercial account or request a quote for large orders. Call 888-815-9763 to speak with a specialist.