In Stock
Can-Fan Max-Fan Inline Fans – 12" Fan
☆☆☆☆☆
$489.53
Can-Fan Max-Fan
Max-Fans are in line mixed-flow fans capable of jaw-dropping performance at high static pressure through innovative design.
The Max-Fan is the first fan that has been developed with a Computational Fluid Dynamics (CFD) program.
Purchase directly from HydroBuilderCan-Fan Max-Fan
Max-Fans are in line mixed-flow fans capable of jaw-dropping performance at high static pressure through innovative design.
The Max-Fan is the first fan that has been developed with a Computational Fluid Dynamics (CFD) program. CFDs are used for engineering aircraft propulsion engines. The perfectly designed 3D blades of the impeller and stator make this fan extremely powerful and energy efficient. Compared with other inline fans, the efficiency is 50%-100% higher. 6″-14″ come pre-wired with an 8 ft 120 V power cord. Can-Fan® bring its innovation to market and sets a new standard for performance. The Max-Fan® is a more powerful and efficient fan that takes less energy to run.
The Can Fan Max-Fans are available in a wide range of sizes
120 Volt
Can-Fan Max-Fan 6″ 334 CFM
Can-Fan Max-Fan 8″ 667 CFM
Can-Fan Max-Fan 8″ HO 932 CFM – 3 Speed
Can-Fan Max-Fan 10″ 1019 CFM
Can-Fan Max-Fan 12″ 1708 CFM
Can-Fan Max-Fan 14″ 1700 CFM
240 Volt Volt
Can-Fan Max-Fan 10″ 240V 1100 CFM
Can-Fan Max-Fan HO “The Beast” 14″ 240V 3343 CFM
Can-Fan Max-Fan 16″ 240V 2436 CFM
Can-Fan Max-Fan 18″ 240V 3665 CFM
Can-Fan Max-Fan 20″ 240V 4688 CFM
The 240 Volt Max-Fans can bring energy efficiency to larger systems. These high-powered Max-Fans™ potentially save hundreds of dollars each year in energy costs using a lightweight aluminum housing. Comes with a 6 ft power cord (240 V).
Detailed specifications & recommended Can Fan Filters for all Max Fans are near the bottom of this page.
All Can Fan Inline Fans are speed controllable. The 12" Max-Fan required the use of the variable transform controller. Only use a speed or motor control of the proper amperage to adjust the speed of the fans.
Details
Manufactured in Germany
Extremely energy efficient
Optimized mixed flow is quieter than comparable fans
Very high aerodynamic efficiency
Lower operational cost than traditional centrifugal fans
Easy installation
5-year warranty
Determining your requirement - Exhaust vs Recirculating (Scrubbing)
You will need to determine whether or not you are exhausting (going from a contaminated environment to a sterile environment in only a single pass through the filter) or recirculating, aka “scrubbing” (exhausting the system back into the contaminated space).
Exhaust
In an exhaust setting the air only passes through the filter one time so it is imperative that we remove as close to 100% of the contaminate as possible with that one chance. This requires that the contaminant have a certain time in contact with the carbon in order to be fully adsorbed. Our filters are marked with both exhaust and recirculating ratings for just this reason. If you are using this system to exhaust, DO NOT exceed the exhaust rating for the filter, the more this rating is exceeded the less contaminant will be adsorbed because the two will not have enough contact timefor adsorption to fully take place.
Recirculating
In a recirculating system, the contact time is not such a crucial number as we are taking contaminated air, filtering it, and releasing it back into what is typically and constantly decontaminated environment. It is for this reason that it is not necessary to remove 100% of the contaminant in a single pass. Instead we double the exhaust rating which will reduce the contact time, the goal here is to still remove a large portion of the contaminant but to get raise the cycle rate of air through the filter above the rate of emission from the source. Now, instead of removing 99.9% of the contaminant in a single pass we are getting closer to 60% but we are getting twice as many cycles through the filter in the same amount of time and over time, reducing the overall build-up of contaminant in the environment.
Sizing Your Space
Once you’ve determined the type of system you need, it’s time to size your space.
Typically for exhaust we recommend a simple length x width x height /3 calculation. This will give you the amount of air (cubic feet per minute, CFM) that you will need to move to properly ventilate your space allowing for a three-minute air exchange (all the air in the space is exchanged for fresh air every three minutes). This is the number you will match your filter to.
Example:
Room size: 10’x12’x8’ (960 cubic feet)
960 cubic feet / 3 minutes = 320CFM (Minimum recommended CFM to exchange the air every 3 minutes)
For recirculating systems, you can use the same length x width x height but divide by 1.5. This will give you a high cycle rate while still ensuring the removal of a majority of contaminant with each pass through the filter.
Model Specifications
Can-Fan Max-Fan 8″ 667 CFM
CFM:
667 at 0wg
RPM:
3250
Maxx Watts:
179
Amps:
1.5 @ 120v AC 60 Hz
Diameter
8"
Outside Diameter:
30.5 cm / 12″
Length:
8.875″
Blade Design:
Mixed Flow
Housing:
Plastic
Inlet/Outlet
8″
Recommended Filters
Recirculating
Can-Lite 8×25
Can 66
Can 50
Can-Lite 8×40
Exhaust
Can 75
Can 100
Can 125
Can-Fan Max-Fan 8″ HO 932 CFM – 3 Speed
Speed
High
Medium
Low
CFM:
932 at 0wg
849 at 0wg
749 at 0wg
RPM:
2935
2705
2460
Maxx Watts:
213
188
178
Amps:
1.87 @ 120v AC 60 Hz
1.71 @ 120v AC 60Hz
1.62 @ 120v AC 60Hz
Diameter
8"
Outside Diameter:
30.5 cm / 12″
Length:
8.875″
Blade Design:
Mixed Flow
Housing:
Plastic
Inlet/Outlet
8″
Recommended Filters
Recirculating
Can-Lite 8×25
Can 66
Can 50
Can-Lite 8×40
Can 75
Exhaust
Can 100
Can 125
Can 1505
Can-Fan Max-Fan 10″ 1019 CFM
CFM:
1019 at 0wg
RPM:
2990
Maxx Watts:
228
Amps:
1.9 @ 120v AC 60 Hz
Sones:
11.5 at 0.10 wg
Diameter
10"
Length:
8.5″
Blade Design:
Mixed Flow
Housing:
Galvanized
Inlet/Outlet
10″
Recommended Filters
Recirculating
Can 50
Can 75
Can-Lite 8×40
Exhaust
Can 100
Can 125
Can 150
Can-Fan Max-Fan 12″ 1708 CFM
CFM:
1708 at 0wg
RPM:
3374
Maxx Watts:
489
Amps:
4.1 @ 120v AC 60 Hz
Diameter
12"
Length:
12.125″
Blade Design:
Mixed Flow
Housing:
Galvanized
Inlet/Outlet
12″
Recommended Filters
Recirculating
Can 75
Can 100
Can-Lite 12x40
Can 125
Can 150
Exhaust
Can-Lite 14×50 XL
Can-Fan Max-Fan 14″ 1700 CFM
CFM:
1786 at 0wg
RPM:
1700
Maxx Watts:
253
Amps:
2.1 @ 120v AC 60 Hz
Sones:
10 at 0.10wg
Diameter
14"
Length:
15.75″
Blade Design:
Mixed Flow
Housing:
Galvanized
Inlet/Outlet
14″
Recommended Filters
Exhaust
Can 150
Can-Lite 14×50 XL
Recirculating
Can 100
Can 125
Can-Lite 14x40
240 Volt models
Can-Fan Max-Fan 10″ 240 Volt
CFM:
1100 at 0wg
RPM:
2990
Maxx Watts:
160
Amps:
0.8 @ 234v AC 50 Hz
Max Ambeint Temp:
50˚C / 122˚F
Diameter
10"
Length:
8.5"
Blade Design:
Mixed Flow
Housing:
Galvanized
Inlet/Outlet
10″
Recommended Filters
Exhaust
Can 100
Can 125
Can 150
Exhaust
Can 50
Can 75
Can-Lite 14x40
Can-Fan Max-Fan HO “The Beast” 14″ 240 Volt 3343 CFM
CFM:
3343 at 0wg
Maxx Watts:
960
Amps:
5.4 @ 240v AC 50 Hz
Diameter
14"
Max Ambeint Temp:
45˚C / 105˚F
Length:
15.75″
Blade Design:
Mixed Flow
Housing:
Galvanized
Inlet/Outlet
14″
Recommended Filters
Recirculating
Max 2500
Can 150
Can-Lite 14×50 XL
Can-Fan Max-Fan 16″ 240 Volt 2436 CFM
CFM:
2436 at 0wg
RPM:
1680
Maxx Watts:
347
Amps:
1.5 @ 240v AC 60 Hz
Max Ambeint Temp:
80˚C / 176˚F
Diameter
16"
Length:
16.375″
Blade Design:
Mixed Flow
Housing:
Aluminum
Inlet/Outlet
16″
Recommended Filters
Recirculating
Max 2500
Can-Fan Max-Fan 18″ 240V 3665 CFM
CFM:
3665 at 0wg
RPM:
1680
Maxx Watts:
700
Amps:
3.0 @ 240v AC 60 Hz
Max Ambeint Temp: