Durban Poison® OfficialDried Flower — Official Reference Spot Price
$3.24USD / g▲ +0.00 (+0.00%)
Find Stockists
Durban Poison | iNkosi yeSativa
Shop›Ruck Air Movement Classic Centrifugal Fan – 4" Fan - High Output
Ruck Air Movement Classic Centrifugal Fan – 4" Fan - High Output
Out of Stock

Ruck Air Movement Classic Centrifugal Fan – 4" Fan - High Output

☆☆☆☆☆

Category: Grow Equipment·Servings: 4" Fan - High Output·Seller: HydroBuilder·Made By: Ruck Air Movement·Location: United States

$93.31

The Established Centrifugal Fan The Classic Fans from Ruck Air Moveemnt will help ensure your plants have a constant supply of fresh air in your grow area. These fans have high quality powder coated metal casing and high efficiency backward curved impellar blades.
Purchase directly from HydroBuilder

Share:WhatsApp·Facebook·

The Established Centrifugal Fan The Classic Fans from Ruck Air Moveemnt will help ensure your plants have a constant supply of fresh air in your grow area. These fans have high quality powder coated metal casing and high efficiency backward curved impellar blades. The efficeint AC motor and included mounting brackets make the Classic Fans from Ruck an easy choice. Available in the following sizes: 4" 4" High Output 6" 6" High Output 8" 8" High Output What is a Centifugal fan? The pressure of an incoming airstream is increased by a fan wheel, a series of blades mounted on a circular hub. Centrifugal fans move air radially — the direction of the outward flowing air is changed, usually by 90°, from the direction of the incoming air. The airflow created by centrifugal fans is directed through a system of ducts or tubes. This helps create a higher pressure airflow than axial fans. Despite a lower flow rate, centrifugal fans create a steadier flow of air than axial fans. Centrifugal fans also require a higher power input. Specifications: VT-IFRC-4 VT-IFRCHO-4 VT-IFRC-6 CFM: 123 CFM: 165 CFM: 263 RPM: 2124 RPM: 2623 RPM: 2552 120V / 0.6A / 75W 120V / 0.7A / 80W 120V / 0.7A / 78W VT-IFRCHO-6 VT-IFRC-8 VT-IFRCHO-8 CFM: 381 CFM: 527 CFM: 765 RPM: 2552 RPM: 3107 RPM: 3107 120V / 1.13A / 126W 120V / 1A / 115W 120V / 2.44A / 277W Determining your requirement - Exhaust vs Recirculating (Scrubbing) You will need to determine whether or not you are exhausting (going from a contaminated environment to a sterile environment in only a single pass through the filter) or recirculating, aka “scrubbing” (exhausting the system back into the contaminated space). Exhaust In an exhaust setting the air only passes through the filter one time so it is imperative that we remove as close to 100% of the contaminate as possible with that one chance. This requires that the contaminant have a certain time in contact with the carbon in order to be fully adsorbed. Our filters are marked with both exhaust and recirculating ratings for just this reason. If you are using this system to exhaust, DO NOT exceed the exhaust rating for the filter, the more this rating is exceeded the less contaminant will be adsorbed because the two will not have enough contact timefor adsorption to fully take place. Recirculating In a recirculating system , the contact time is not such a crucial number as we are taking contaminated air, filtering it, and releasing it back into what is typically and constantly decontaminated environment. It is for this reason that it is not necessary to remove 100% of the contaminant in a single pass. Instead we double the exhaust rating which will reduce the contact time, the goal here is to still remove a large portion of the contaminant but to get raise the cycle rate of air through the filter above the rate of emission from the source. Now, instead of removing 99.9% of the contaminant in a single pass we are getting closer to 60% but we are getting twice as many cycles through the filter in the same amount of time and over time, reducing the overall build-up of contaminant in the environment. Sizing Your Space Once you’ve determined the type of system you need, it’s time to size your space. Typically for exhaust we recommend a simple length x width x height /3 calculation. This will give you the amount of air (cubic feet per minute, CFM) that you will need to move to properly ventilate your space allowing for a three-minute air exchange (all the air in the space is exchanged for fresh air every three minutes). This is the number you will match your filter to. Example: Room size: 10’x12’x8’ (960 cubic feet) 960 cubic feet / 3 minutes = 320CFM (Minimum recommended CFM to exchange the air every 3 minutes) For recirculating systems, you can use the same length x width x height but divide by 1.5. This will give you a high cycle rate while still ensuring the removal of a majority of contaminant with each pass through the filter.

Related products

Inline Tap – 12mm/15mm In-Line TapIn Stock

Inline Tap – 12mm/15mm In-Line Tap

12mm/15mm In-Line Tap

☆☆☆☆☆

Category: Grow Equipment·Seller: Hydroponic.co.za·Location: South Africa

R 20.00

$1.21

Read More
Net Pots – Black Net Pot – 3LIn Stock

Net Pots – Black Net Pot – 3L

Black Net Pot – 3L

☆☆☆☆☆

Category: Grow Equipment·Seller: Hydroponic.co.za·Location: South Africa

R 30.00

$1.82

Read More
Jiffy C – 1 – 99In Stock

Jiffy C – 1 – 99

1 – 99

☆☆☆☆☆

Category: Grow Equipment·Seller: Hydroponic.co.za·Location: South Africa

R 2.00

$0.12

Read More
Ducting Reducer – Ducting Reducer 315mm – 250mmIn Stock

Ducting Reducer – Ducting Reducer 315mm – 250mm

Ducting Reducer 315mm – 250mm

☆☆☆☆☆

Category: Grow Equipment·Seller: Hydroponic.co.za·Location: South Africa

R 400.00

$24.25

Read More
Durban Poison Official Seal

iNkosi yeSativa Co-operative Collective

GLOBAL SOURCING DIRECTORATE & COMPLIANCE REGISTRY DESK

Administrative Regional Headquarters: Durban, KwaZulu-Natal, Republic of South Africa Statutory Notice: Established under the Co-operatives Act of South Africa to govern the genetic, economic, and traditional heritage sovereignty of indigenous landrace crops. All global compliance filings, trademark auditing parameters, and decentralized territorial distribution agreements are administered exclusively through this centralized registry gateway.

Geographical Indication (GI) Protected Designation of Origin (PDO) status for:

Durban Poison | iNkosi yeSativa Co-operative

Cultivation Limited to within the defined geographic limits of KwaZulu-Natal, South Africa. All Cultivators must be registered and operate under the iNkosi yeSativa Co-op, and products must carry the official iNkosi yeSativa Seal. Cultivators can choose to become members (shareholders) of iNkosi yeSativa Co-op. There is no cost.

Copyright 1993–2026 ©Durban Poison GI Official, iNkosi yeSativa Co-op, (The King of Sativa) KwaZulu-Natal, South Africa

Welcome to the official Durban Poison website.

To visit our website, you must be of legal age to consume cannabis in your country of residence. If no such laws exist in your country, you must be over 21.

Are you of legal age to consume cannabis?

Cannabis abuse is hazardous to your health. Please enjoy responsibly.